Switch any electrical load with absolute confidence. KRIPAL manufactures a comprehensive lineup of heavy duty magnetic contactors and protection relays engineered for continuous operations. From standard AC contactors and reversing modules for motor control to high voltage DC units for renewable energy applications, we supply the exact hardware you need. Supported by specialized capacitor switches, definite purpose air conditioner contactors, manual starters, and auxiliary blocks, we cover your entire component requirement.

Get A Quote
UKH-150 Thermal Overload Relay 34-150A Contact Rating 3P 1NO + 1NC
  • certificate

UKH-150 Thermal Overload Relay 34-150A Contact Rating 3P 1NO + 1NC

UKH Thermal Overload Relay is manufactured in compliance with the GB/T 14048.4 standard.

Ask a Quote
UKH-220 Thermal Overload Relay 65-240A Contact Rating 3P 1NO + 1NC
  • certificate

UKH-220 Thermal Overload Relay 65-240A Contact Rating 3P 1NO + 1NC

UKH Thermal Overload Relay is manufactured in compliance with the GB/T 14048.4 standard.

Ask a Quote
UKH-630 Thermal Overload Relay 220-630A Contact Rating 3P 1NO + 1NC
  • certificate

UKH-630 Thermal Overload Relay 220-630A Contact Rating 3P 1NO + 1NC

UKH Thermal Overload Relay is manufactured in compliance with the GB/T 14048.4 standard.

Ask a Quote
UKH-100 Thermal Overload Relay 34-125A Contact Rating 3P 1NO + 1NC
  • certificate

UKH-100 Thermal Overload Relay 34-125A Contact Rating 3P 1NO + 1NC

UKH Thermal Overload Relay is manufactured in compliance with the GB/T 14048.4 standard.

Ask a Quote
UKH-22 Thermal Overload Relay 0.1-22A Contact Rating 3P 1NO + 1NC UL Listed
  • certificate
  • certificate
  • certificate

UKH-22 Thermal Overload Relay 0.1-22A Contact Rating 3P 1NO + 1NC UL Listed

UKH Thermal Overload Relay is manufactured in compliance with the GB/T 14048.4 standard.

Ask a Quote
UKH-40 Thermal Overload Relay 4-40A Contact Rating 3P 1NO + 1NC UL Listed
  • certificate
  • certificate
  • certificate

UKH-40 Thermal Overload Relay 4-40A Contact Rating 3P 1NO + 1NC UL Listed

UKH Thermal Overload Relay is manufactured in compliance with the GB/T 14048.4 standard.

Ask a Quote
UKH-85 Thermal Overload Relay 7-85A Contact Rating 3P 1NO + 1NC UL Listed
  • certificate
  • certificate
  • certificate

UKH-85 Thermal Overload Relay 7-85A Contact Rating 3P 1NO + 1NC UL Listed

UKH Thermal Overload Relay is manufactured in compliance with the GB/T 14048.4 standard.

Ask a Quote
UKC1-100R 3-Pole Reversing Contactor 100A ac Coil 24V 110V 220V 380V
  • certificate

UKC1-100R 3-Pole Reversing Contactor 100A ac Coil 24V 110V 220V 380V

Its interlocked contact design prevents simultaneous closure, ensuring reliable and safe forward/reverse operation for industrial applications.

Ask a Quote
UKC1-85R 3-Pole Reversing Contactor 50/65/75/85A ac Coil 24V 110V 220V 380V
  • certificate

UKC1-85R 3-Pole Reversing Contactor 50/65/75/85A ac Coil 24V 110V 220V 380V

Its interlocked contact design prevents simultaneous closure, ensuring reliable and safe forward/reverse operation for industrial applications.

Ask a Quote

Download Catalog

For more information, please download the album.

INDUSTRIAL SWITCHING COMPONENTS. FACTORY DIRECT.

Complete Load Switching Solutions for Industrial Equipment Manufacturers

Modern industrial equipment rarely handles just one type of circuit. Engineers frequently have to mix high inrush inductive motors, heavy capacitive banks, and specialized direct current lines inside their designs. KRIPAL solves this sourcing headache by manufacturing a fully coordinated control portfolio. Our factory controls the entire manufacturing process using premium silver alloy contacts and optimized magnetic coils to guarantee stable drop out times, low heat dissipation, and dependable performance across all utilization categories.

Complete Load Switching Solutions for Industrial Equipment Manufacturers

Custom Motor Control and Protection Assemblies

We configure our switching components and overload relays to simplify assembly and prevent common field failures. Our hardware directly solves your real-world panel bottlenecks:

  • Prevent Contact Welding: Our AC and DC contactors use heavy silver alloy contacts to quench electrical arcs during frequent motor cycles before they can damage your hardware.
  • Lock Out Short Circuits: Our reversing combinations rely on physical mechanical interlocks and auxiliary cutouts, preventing both contactor groups from closing together during rotation changes.
  • Eliminate False Tripping: Our thermal overload relays use temperature compensation strips to ensure bimetallic elements react strictly to actual motor faults, preventing nuisance trips in hot outdoor panels.
  • Absorb Voltage Surges: For capacitor switching, our contactors use early make terminals wired with damping resistors to absorb massive current spikes before the main contacts close.
  • Save Installation Space: We manufacture mini contactors rated up to 32A alongside snap on auxiliary blocks, letting you fit full motor control into crowded enclosures with strict space limits.

Frequently Asked Questions

Explore FAQ >
A relay is typically used for switching control or signal-level circuits, while a contactor is designed to switch higher current loads such as motors, heating elements, and power circuits. Contactors are commonly used in industrial and commercial applications where frequent switching is required.
Selection depends on the load type, rated current and voltage, control coil voltage, number of poles, and the application environment. For motor applications, factors such as starting current and duty cycle should also be considered.
Yes. We supply AC contactors for general power switching, motor control, and HVAC systems, as well as DC contactors for battery systems, DC motors, and DC control circuits.
Reversing contactors are used to change motor rotation direction by reversing the phase sequence. They are commonly applied in conveyors, hoists, elevators, gates, and other equipment requiring forward and reverse operation.
Thermal overload relays are used to protect motors from overload and phase-loss conditions. They are typically paired with contactors in motor starter assemblies to help prevent motor damage.
Yes. Miniature contactors are designed for space-limited panels and lower current applications, typically from 9A to 32A. They are widely used in control panels, HVAC units, and compact OEM equipment.
Yes. Our contactors and relays are manufactured in accordance with IEC and other applicable international standards, supporting safe and reliable operation across global markets.
Auxiliary contacts can be added to provide status indication, interlocking, and feedback signals within control circuits.

Recent Blog

Explore Blog >
Contactor vs Circuit Breaker vs Isolator Switch: Understanding the Difference in Industrial Power

Contactor vs Circuit Breaker vs Isolator Switch: Understanding the Difference in Industrial Power

Understand the key differences between a Contactor, Circuit Breaker, and Isolator Switch in industrial power systems. Learn their distinct functions and proper applications.

AC Coil vs DC Coil Contactors Technical Selection Guide

AC Coil vs DC Coil Contactors Technical Selection Guide

Compare AC coil and DC coil contactors. Learn their key technical differences, advantages, and how to select the right one for your electrical control...

AC Contactors and Thermal Overload Relays Selection Guide with Star Delta Solutions

AC Contactors and Thermal Overload Relays Selection Guide with Star Delta Solutions

Master the selection of contactors and overload relays in your Star Delta starter setup to avoid sizing errors and ensure optimal performance.

High Voltage DC Contactors vs DC Coil AC Contactors

High Voltage DC Contactors vs DC Coil AC Contactors

Compare High Voltage DC Contactors and DC Coil AC Contactors. Learn their key differences, applications, and how to choose the right one for your...

How Do Lighting Contactors Differ from Motor Contactors?

How Do Lighting Contactors Differ from Motor Contactors?

Explore the key differences between lighting contactors and motor contactors, including their applications and electrical ratings in lighting contactor vs motor contactor.

Direct from Manufacturer

How Can We Assist You?

Tell us a bit more so we can route your request to the right engineer. Get factory-direct pricing and custom specifications within 24 hours.