The KRIPAL KCT Series Zero-Phase Current Transformer (ZCT) is a core sensing component specifically designed to work seamlessly with earth leakage relays (such as the KLR series). This series is available in three different inner diameter sizes (KCT40, KCT55, and KCT80) for accurate detection of residual current (earth leakage current) in AC electrical systems. When a cable passes through the transformer, the KCT captures minute leakage signals and outputs them to the relay, thereby triggering a fault trip or alarm. Its rated turns ratio can be customized according to user requirements. Featuring high accuracy, high withstand voltage, and strong anti-interference capabilities, it is an essential basic component for ensuring the safety of low-voltage distribution systems.

Get A Free Quote WhatsApp

Share quantity, voltage and destination — we reply with MOQ, lead time and OEM options.

Key Features

  • Multiple Sizes Available: Inner diameters of 40mm, 55mm, and 80mm, supporting maximum cable feed-through currents up to 630A.
  • High Accuracy & Reliability: Accuracy class 5P and 10P when an external resistor is connected, with an accuracy limit factor (ALF) of up to 10.
  • Flexible Resistor Configuration: For 300mA, 3A, and 30A residual current inputs, supports a built-in 56Ω resistor or external 5.6Ω/0.5Ω resistors used with KLR series relays.
  • Robust Electrical Performance: Highest voltage for equipment 0.72kV, rated power-frequency withstand voltage 3kV, operating temperature -25°C to +40°C.
  • Easy Installation: Base-fixed design with M3.5/M4 mounting holes for distribution cabinets.

Applications

  • Industrial Power Distribution & Machinery Control: Paired with KLR series earth leakage relays for ground fault monitoring in factory distribution cabinets and mechanical equipment.
  • Building Electrical & Infrastructure: Main incoming or branch circuit leakage protection in commercial buildings and infrastructure projects.
  • Three-Phase Four-Wire Systems: Through-type installation for zero-phase current detection and leakage protection in AC power grids.

Specifications & Drawings

Parameter Specification
Rated Frequency 50/60Hz
Accuracy Class 5P, 10P (When an external resistor is connected)
Rated turns ratio 1/210 (Can be customized)
Residual current input / output voltage sensing 300mA/80mV, rated resistive burden 56Ω (installed in KCT)
3A/80mV, rated resistive burden 5.6Ω (external, installed in KLR523)
30A/80mV, rated resistive burden 0.5Ω (external, installed in KLR523)
Rated primary current 0.3A
Rated accuracy limit primary current 3A
Accuracy limit factor (ALF) 10
Highest voltage for equipment 0.72kV
Rated power-frequency withstand voltage 3kV
Operating Temperature -25 ~ +40°C

Need this model for a project?

Send the pole configuration, current rating and order quantity. A KRIPAL engineer will come back with pricing and lead time.

Request A Quote

Related Products

Industry Solutions

Power Distribution Networks

Industrial Facilities & Heavy Machinery

Building Management & Intelligent Construction

OEM & Control Panel Manufacturing

Power Distribution Networks

Power Distribution Networks

Enabling the Intelligent Flow of Energy As energy systems evolve into dynamic, data-driven networks, power distribution is no longer a one-way street. Modern grids must balance renewable generation, energy storage, electric mobility, and real-time consumption with unprecedented precision. Kripal Electric delivers the electrical foundation for this transformation — connecting infrastructure, protection, and intelligence into one… Continue reading KCT40 KCT55 KCT80 Zero-Phase Current Transformer | Residual Current Sensor for Earth Leakage Protection

Industrial Facilities & Heavy Machinery

Industrial Facilities & Heavy Machinery

Power That Drives Performance Modern industries depend on continuous energy flow to power production lines, foundries, fabrication plants, and large mechanical systems. Equipment downtime translates directly to productivity loss, making electrical reliability and safety a core requirement for success. Kripal Electric provides end-to-end low-voltage protection and control solutions for industrial facilities and heavy-duty machinery, delivering… Continue reading KCT40 KCT55 KCT80 Zero-Phase Current Transformer | Residual Current Sensor for Earth Leakage Protection

Building Management & Intelligent Construction

Building Management & Intelligent Construction

Smarter Power for a Connected Future The modern built environment is no longer static. Buildings today think, respond, and adapt. From commercial towers and hospitals to smart campuses and residential complexes, construction is evolving toward systems that integrate energy efficiency, automation, and safety. Kripal Electric supports this transformation with advanced low-voltage electrical solutions that form… Continue reading KCT40 KCT55 KCT80 Zero-Phase Current Transformer | Residual Current Sensor for Earth Leakage Protection

OEM & Control Panel Manufacturing

OEM & Control Panel Manufacturing

Empowering System Builders with Precision and Performance Every control panel or OEM assembly is the command center of an industrial system — the link between power, protection, and performance. In a world of growing automation, electrical panels must do more than distribute energy. They must integrate safety, intelligence, and flexibility. Kripal Electric partners with original… Continue reading KCT40 KCT55 KCT80 Zero-Phase Current Transformer | Residual Current Sensor for Earth Leakage Protection

Direct from Manufacturer

Request a quote

KCT40 KCT55 KCT80 Zero-Phase Current Transformer | Residual Current Sensor for Earth Leakage Protection

Share quantity, destination and any OEM requirement. A KRIPAL engineer will reply with factory-direct pricing and lead time.

Call Get A Quote