KRIPAL UKP AC switch disconnector and isolator switch range

UKP Series · Isolator Switches

KRIPAL AC Switch Disconnectors 10A to 1600A

KRIPAL manufactures the UKP series of AC switch disconnectors with rated currents from 10A to 1600A and 2 to 8 poles. The range covers compact DIN-rail and panel-mount switches, modular mechanical interlock switch-disconnectors, and high-current base-mount units for distribution panels, MCCs and industrial equipment — all designed and manufactured in-house for OEM and private-label supply.

  • IEC 60947-3
  • 10A to 1600A
  • IP65/IP66 Enclosed Options
  • 2P to 8P
  • CE/CB/UKCA/SEMKO
  • OEM Ready

UKP AC Isolator Switch Family. Three Solutions Covering 10A to 1600A.

All three series are AC switch disconnectors / isolator switches for different current ratings and installation scenarios.

UKP 10–150A UKP-50/125/160 UKP 250–1600A
Current 10–150A 10–160A 125–1600A
Poles 2P/3P/4P/5P 2P–8P 2P–6P
Insulation Voltage 690V 800V 1000V
Mounting Enclosed surface mount / DIN Rail / Panel mount Surface / DIN Rail / Panel / Extension Shaft / Metal Enclosed Base mount / Busbar Direct / Metal Enclosed
Special Feature Multiple enclosure styles Mechanical interlock (J...A/J...U/J...S) High-current busbar direct mounting
Load Break Capability No No Yes
Typical Use HVAC, machinery, small panels HVAC, machinery, small panels, Panel builders, dual-power, multi-pole switching Distribution panels, MCC, high-current systems
Certification CE, CB, UKCA, SEMKO CE, CB, UKCA, SEMKO CE, CB, SEMKO
Positioning Standard isolation solution More compact, better aesthetics, enhanced performance High-current, load-break capable, modular distribution isolation solution
UKP 10–150A

IP65 Enclosed · CE·CB·UKCA·SEMKO

UKP 10–150A AC Switch Disconnector

The standard UKP isolator switch range for panel builders, HVAC and OEM equipment — compact rotary switch disconnectors from 10A to 150A with flexible mounting and enclosure options.

  • 4 mounting methods: surface / DIN rail / panel flush / extension shaft
  • Multiple PC enclosure styles for different market aesthetics
  • IP65/IP66 enclosed surface-mount boxes for outdoor and dusty environments
  • Optional key lock to prevent unauthorized operation
Request UKP 10–150A quote
UKP 10-150A IP65 enclosed AC isolator switch

Pick the installation option that fits your distribution cabinet or HVAC application

The UKP 10-150A ON-OFF isolator switch is available in different mounting forms. Select the body that fits your project, then confirm current and poles with our sales team.

UKP 10-150A Panel-mount UKP DIN rail-mount UKP ZAV UKP
UKPX1-40/63/150 UKP0/1/3/5 UKP0/1/3/5 UKP0/1/3/5
Mount: IP65/66 Enclosed Mount: Panel Mount: DIN Rail Mount: Base Mounting with Door Clutch
Current: 10-150A Current: 10-150A Current: 10-150A Current: 10-150A
Poles: 2P-5P Poles: 2P-5P Poles: 2P-5P Poles: 2P-5P
UKP-50/125/160

6P–8P Interlock · Compact · Enhanced Performance

UKP-50/125/160 Mechanical Interlock Switch Disconnector

An upgraded, more compact AC switch-disconnector platform with mechanical interlock and changeover options for dual-power, MTS and multi-circuit switching up to 160A.

  • Smaller footprint, refined appearance and improved performance vs UKP 10–150A
  • Three-position interlock (I–I+II–II / I–O–II) supports MTS dual-source manual changeover
  • IP64–IP67 protection for kitchen, outdoor and dusty environments
  • 6P/8P mechanical combination switches for synchronized multi-circuit switching
Request UKP-50/125/160 quote
UKP-50/125/160 mechanical interlock isolator switch

UKP-50/125/160 Mechanical Interlock & Changeover Solutions

UKP-50-125-160 surface-mount IP66 UKP-50-125-160 Metal enclosure UKP-50-125-160 panel-mount UKP-50-125-160 DIN rail-mount UKP-50-125-160 VZV UKP-50-125-160 Mechanical Interlock
UKP‑50/125/160‑PFL UKPS‑50/125/160 UKP‑50/125/160‑E/Z UKP‑50/125/160‑SMA UKP‑50/125/160‑VZV UKP‑50J /125J /160J
Mount: IP66 PC Enclosed Mount: IP65 Metal Enclosed Mount: Panel Mount: DIN Rail Mount: Base Mounting with Door Clutch Mount: DIN Rail/ IP66 Enclosed/ Door Clutch
Current: 10‑160A Current: 10‑160A Current: 10‑160A Current: 10‑160A Current: 10‑160A Current: 10‑160A
Poles: 2P‑5P Poles: 3P/4P/5P Poles: 2P‑5P Poles: 2P‑5P Poles: 2P‑5P Poles: 6P/8P
UKP 250–1600A

Load-Break Capable · Busbar Direct Mount

UKP 250–1600A Load-Break Switch Disconnector

High-current AC switch disconnectors for main distribution panels, MCCs and switchgear — the only UKP series rated for load-break operation up to 1600A.

  • Only UKP series rated for load-break operation — suitable as a main switch
  • Visible window design for clear ON/OFF status indication
  • Base mount, busbar direct mount and metal-enclosed surface options
  • Stored-energy operating mechanism for fast make/break and arc suppression
Request UKP 250–1600A quote
UKP 250-1600A base mount switch disconnector with visible window

Mounting & Operation Options Across the UKP Range

UKP 250-1600A Front-operate UKP 250-1600A Side-operate UKP 250-1600A Extension Shaft UKP 250-1600A Metal Enclosure UKP 250-800J Changeover Disconnects
Type: Front Operated Type: Side Operated Type: Door‑operated (with extension shaft) Type: Metal Enclosed Type: Changeover Disconnects
Mount: Base/Busbar Direct Mount: Base/Busbar Direct Mount: Base/Busbar Direct Mount: Surface mounting Mount: Base/Busbar Direct
Current: 125–1600A Current: 125–800A Current: 125–1600A Current: 125–1600A Current: 125–800A
Poles: 2P‑6P Poles: 2P/3P/4P Poles: 2P/3P/4P Poles: 3P/4P Poles: 3P/4P

Front vs. Side Operation: Front-operated handles suit standard cabinet layouts; side operation is used when the switch sits close to the cabinet’s rear panel, or when multiple units are densely arranged side by side (as in MCC layouts) where front handles would interfere with each other.

Need a wholesale quote for UKP switch disconnectors?

Send series, current rating, poles, mounting type and quantity. We reply with factory pricing and lead time within one business day.

Request Quote Now

AC Switch Disconnector Applications — Which UKP Series Fits Your Project

The table below matches common electrical applications to the recommended UKP series, based on current rating, mounting method and switching function.

Application Recommended UKP Series Why
Electrical distribution panels UKP 250–1600A High current rating (125–1600A), Base Mount or Busbar Direct Mount for direct busbar connection without transition copper
MCC / Motor Control Centers UKP 10–1600A (mixed, depending on feeder current) Multiple mounting/operating options support dense multi-feeder layouts; Side Operated variants avoid handle interference between adjacent units
HVAC & commercial equipment UKP 10-150A, UKP-50/125/160 Compact footprint, surface or DIN rail mount, multiple enclosure styles for equipment integration
PV isolation / dual power systems UKP-50J...S/125J...S/160J...S or UKP-50J...U/125J...U/160J...U Mechanical interlock guarantees the two power sources cannot be connected together unsafely; J...U provides a guaranteed OFF position between sources
Panel builders & OEM equipment UKP 10–1600A (full range) Full current range under one platform, multiple mounting/operating configurations, OEM/private-label support
Industrial machinery UKP 10-150A,UKP-50/125/160 Compact, DIN rail or panel mount, meets machinery isolation requirements
High-current power distribution / switchgear UKP 250–1600A Base Mount and Busbar Direct Mount standard for high-power circuits; metal enclosed option available
Multi-circuit switching / 6P-8P combined loads UKP-50J...A/125J...A/160J...A Mechanical combination system synchronizes two 3P/4P switches into a single 6P/8P switching action
Cabinets with limited front space Side Operated variants UKP 250-1600 Handle mounted on the side avoids interference when the switch sits close to the back panel or when units are densely packed
Door-mounted external operation Any series + Extension Shaft Shaft extends through the cabinet door with a lockable external handle for safe operator access

B2B inquiry

Request a wholesale quote for UKP switch disconnectors

Tell us the series, current rating, poles, mounting type and quantity. Factory pricing and lead time within one business day.

  • UKP 10–150A
  • UKP-50/125/160 interlock
  • UKP 250–1600A load-break
  • OEM / private label

Email sale3@kripal.com
Tel +86 153 8157 6159

FAQ for B2B buyers

Straight answers for purchasing and engineering teams sourcing UKP AC switch disconnectors and isolator switches.

Which KRIPAL UKP AC switch disconnector should I choose?

Choose based on current and application: UKP 10–150A or UKP-50/125/160 for currents up to 160A in panels, HVAC, or OEM equipment; UKP 250–1600A for main distribution panels or MCCs requiring load-break operation above 125A. The UKP-50/125/160 series is the upgraded, more compact version of the UKP 10–150A range.

Can UKP switch disconnectors be operated under load?

This depends on the series. The UKP 250–1600A series is rated for load-break operation. The UKP 10–150A and UKP-50/125/160 series must not be operated under load — they require the circuit to be de-energized by an upstream breaker or contactor first.

How many poles do I need?

Single-phase circuits typically need 2P, three-phase circuits typically need 3P or 4P (with neutral), and combined/dual-circuit applications may need 6P or 8P.

What does IP65 vs IP66 vs IP67 mean for enclosed isolators?

IP65 protects against dust ingress and low-pressure water jets; IP66 adds protection against powerful water jets; IP67 adds protection against temporary immersion. The UKP-50/125/160PFL series covers this full range (IP64–IP67), while the UKP 10–150A enclosed version is rated IP65/IP66.

What is the maximum insulation voltage across the UKP range?

UKP 10–150A: 690V. UKP-50/125/160: 800V. UKP 250–1600A: 1000V.

Can I combine a UKP isolator with an MCB or fuse in the same enclosure?

Yes. Several UKP variants, including the enclosed metal box series (UKPS-250 to 1600), are commonly installed alongside downstream MCBs or fuses to combine isolation with short-circuit and overload protection in a single distribution box.

Do UKP switches support lockout-tagout (LOTO)?

Yes. Handles across the range support padlocking in the open position (up to 3 padlocks on the metal-enclosed series), satisfying standard LOTO safety procedures during maintenance.

What is the difference between Base Mount and Busbar Direct Mount?

Base Mount bolts the complete switch base directly to a metal mounting plate inside the panel. Busbar Direct Mount uses a removable base with extended bare-copper terminals that stack directly onto the panel's busbars, eliminating the need for transition copper bars — commonly used in high-current circuits.

When should I use an extension shaft?

An extension shaft is used when the operating handle needs to be accessible from outside the cabinet door, allowing safe lockable operation without opening the panel.

When should I choose side operation instead of front operation?

Side operation is used when the switch sits too close to the cabinet's back panel for front access, or when multiple switches are densely arranged side by side (as in MCC layouts) and front handles would interfere with each other.

What is a mechanical interlock switch?

Mechanical interlock switch (UKP-50J...S/125J...S/160J...S or UKP-50J...U/125J...U/160J...U) uses a mechanical linkage between two switch-disconnectors to guarantee that two power sources cannot be connected to the same load at the same time, typically used in dual-power or generator/mains changeover applications.

Which certifications do UKP switches hold?

UKP 10–150A and UKP-50/125/160 are certified to CE, CB, UKCA and SEMKO. UKP 250–1600A is certified to CE, CB and SEMKO. Confirm the exact certificate scope for your required model with our technical team.

What standards do UKP metal-enclosed switches comply with?

The UKPS-250 to 1600 metal-enclosed series complies with IEC 60947-1 and IEC 60947-3.

Can KRIPAL supply UKP switches under a private label / OEM brand?

Yes, the full UKP range is manufactured in-house and available for OEM and private-label supply, including custom enclosure branding and packaging.

Request Quote